Location -> Industrial online analyzer -> 2.Chlorine sensor

Type:Chlorine sensor
Illustrate:It can online monitor the residual chlorine concentration for the drink water ,water disinfection in industrial process .
CXNS-70 Chlorine sensor
·Application
It can online monitor the residual chlorine concentration for the drink water ,water disinfection in industrial process . It can also used in the swimming pools where the place need to measure the residual chlorine concentration.
·Measuring principle
CXNS-70 type oxygen electrode is a diaphragm polarographic (clark) sensor . It is consisted of cathode , anode , electrolyte and a layer of gas permeability diaphragm on the cathode . The measured residual chlorine diffuse to the cathode through diaphragm .The proper polarization voltage between the cathode and the anode ,which can deoxidize the residual chlorine on the cathode . These chemical actions proportional to the residual chlorine which is in the measured medium .·Feature
★ Sensitive response ,good stability
★ Do not need to replace the diaphragm and the electrolyte .
★ Suitable for variety of waste water , the diaphragm is difficult to be damaged, anti-pollution .
·Technical parameters
Response time :90%﹤2min(room temperature ),95%﹤5min(room temperature)
Operating temperature:2~45℃
Min velocity:200~250ml/min,flow-through flow can not less than 30L/h
pH range:4~8.2pH
Proof pressure range:0~1bar
Temperature compensation: Thermal resistance value can be customize by the requests .
Electrode cable :3m high impedance and low noise shielded cable . Electrode size :Diameter 20mm ,length 70mm
Electrode material :316L stainless steel shell ,POM diaphragm cap ,PTFE diaphragm .
·Application
It can online monitor the residual chlorine concentration for the drink water ,water disinfection in industrial process . It can also used in the swimming pools where the place need to measure the residual chlorine concentration.
·Measuring principle
CXNS-70 type oxygen electrode is a diaphragm polarographic (clark) sensor . It is consisted of cathode , anode , electrolyte and a layer of gas permeability diaphragm on the cathode . The measured residual chlorine diffuse to the cathode through diaphragm .The proper polarization voltage between the cathode and the anode ,which can deoxidize the residual chlorine on the cathode . These chemical actions proportional to the residual chlorine which is in the measured medium .·Feature
★ Sensitive response ,good stability
★ Do not need to replace the diaphragm and the electrolyte .
★ Suitable for variety of waste water , the diaphragm is difficult to be damaged, anti-pollution .
·Technical parameters
Measurement: | HOCl/residual chlorine | Minim HOCl/residual chlorine |
Range: | 0.05~20ppmHOCl | 0.01~5ppm |
Polarization time: | First time 30min | First time 90min |
Second time 10min | Second time 45min |
Operating temperature:2~45℃
Min velocity:200~250ml/min,flow-through flow can not less than 30L/h
pH range:4~8.2pH
Proof pressure range:0~1bar
Temperature compensation: Thermal resistance value can be customize by the requests .
Electrode cable :3m high impedance and low noise shielded cable . Electrode size :Diameter 20mm ,length 70mm
Electrode material :316L stainless steel shell ,POM diaphragm cap ,PTFE diaphragm .