Type:CX-ULM-RHN ultrasonic level meters

Illustrate:distance accuracy online revise in different environment(customized).

CX-ULM-RHN Ultrasonic Level Meters
 
 
                     
  
◆The main function characteristics:
·distance accuracy online revise in different environment(customized).
·Automatically follow the environment temperature to compensate the distance value.
·Differential value can be set, RS series has equipped with Flange plate, other series all have screw fastening, 
can be applied directly in liquid level measurement, easy mounting. It also has selections of added value/differential 
value distance measurement model, can be used in distance and level measurement.
·2 route or 4 route limiting value setting, can be applied in liquid level either with section control or line control.
·RS485/232 Serial signal output or 4~20mA and 0~20mA analog quantity output or 1~5V and 0~5V analog quantity output(optional).
·Functions of "echo intelligent recognition" and "middle slope" digital filtering function.
·For different measurement objects, customers can set the measure period from 100~0.1 times/second.
·Select PC serial output and conversion attachment, the networking with principal unit can be realized directly.
·Select PC serial output and conversion attachment, the networking with principal unit can be realized directly.
·keyboard operation, display can be shut down during operation to save energy.
·With selection of 1~15 level transmitting power, it can be revised anytime according to different operation environment.
·Full measure range starting point and ending point digitalize translatory function.
·sound velocity transition region temperature compensation digital adjustment platform.
·Abundant information on LCD display, including level, weight, temp, current, voltage, limiting value switching situation etc.
·Serial signals sending could be PTP,BUS type.
 
◆The main technical indexes:
liquid level measurement range: 5m,7m,10m,12m,15m(Under clean environment, with rigid and smooth 
objective surfacecorresponding wave beam projected area)
Flow precision:Better than 0.5% FS(at times, and the blind process ℃)
Probe blind area:≤300~800mm (varies from different measure range and sensor,at 25 ℃)
Output signal: 4~20Ma(tow,three, four-wire),0~5V,RS485, switch value ---(optional)
Showing the way: LCD display+backlight
Working temperature: 0 ~ + 50 ℃(wider temperature range can be customized)
Work power:DC24V / 300 mA(default);DC12V/300mA(optional)
Protection level:Sensor IP65(design level,shelter needed)
Cable way: water proof connect port, down-lead 0.5m(default, added down lead can be customized)
Mounting model: screw,or sifter clamping
Application environment: constant pressure, NOT explosion-proof, Non erosive environment:
 

Last:CX-ULM-RJFG separate wall hangi.. Next:CX-ULM-R ultrasonic level meter..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
18女下面流水不遮图免费观看,99久久精品免费看国产一区二区三区,无限资源好看片高清在线,婷婷射精AV这里只有精品,国产精品天天影视久久综合网