Gas Turbine Flow Meter Application Occasions

Shanghai Cixi is a professional manufacturer of flow meters. Today Winny will introduce the main applications of gas turbine flow meters.
sales01@cxflowmeter.com
First of all, what are the main disadvantages of gas turbine flow meters?

 
1. To maintain the calibration characteristics for a long time, regular calibration is required. Suspended substances or corrosive components contained in the medium will cause problems such as bearing wear and jamming, which will change its accuracy and
Limiting its scope of application, although the situation has improved after the use of wear-resistant hard alloy shafts and bearings, this problem still exists. Therefore, it must be calibrated regularly, for trade storage and transportation and high precision
For measurement requirements, it is best to equip with on-site calibration equipment.

 
 
2. Regularly add oil to ensure adequate lubrication of the bearing to ensure measurement accuracy and prolong service life.
 
3. The physical characteristics of the medium (such as density, viscosity, etc.) have a greater impact on the characteristics of the turbine flowmeter.
Gas flow meters are easily affected by density and are closely related to temperature and pressure, so temperature and pressure corrections are required.
 
1. The gas turbine flowmeter is greatly affected by the flow field distribution. Therefore, for the flowmeter without a rectifier at the inlet, straight pipe sections
should be installed on the upstream and downstream sides of the sensor as required, and for the flowmeter with a rectifier for the inlet design, the flowmeter
should also be The length of the straight pipe shall be set as required by the instructions for use.
 
2. It is not suitable for use in occasions where there is a strong pulsating flow, nor is it suitable for the measurement of mixed-phase flow.
 
3. The cleanliness of the measured medium is relatively high, and the filter needs to be installed as required, but this also brings about an increase in pressure loss.
 
4. The flow characteristics of small-diameter turbine flowmeters are seriously affected by physical properties, so it is difficult to improve the performance of small-diameter
turbine flowmeters. For example, the smallest diameter is DN25, but its range is only
10:1, the accuracy is only up to ±1.0%.


If you want to know more parameters and quotations of different models, please consult winny: sales01@cxflowmeter.com


 

Last:Advantages and limitations of v.. Next:Application of gas mass flow me..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
18女下面流水不遮图免费观看,99久久精品免费看国产一区二区三区,无限资源好看片高清在线,婷婷射精AV这里只有精品,国产精品天天影视久久综合网