Location -> Products -> Analyzer Instrument -> On-line Instrument -> Industry Conductivity Meter

Type:CX-ICM-1104 industrial conductivity meter
Illustrate:It can be widely used for continuous monitoring of the conductivity values of the solutions used in the following industries: thermal power plants, chemical industry, chemical fertilizer, metallurgy, environmental protection, pharmacy manufacturing, biochemistry, foodstuff and running water.
CX-ICM-1104 industrial conductivity meter
Main features1.Fully intelligent: It adopts high-precision AD conversion and single chip microcomputer processing technologies
2.It can be used for conductivity and temperature measurement, automatic temperature compensation, automatic range switching, self-checking, etc.
3.Multi-parameter display
4.values with red 10 x 10mm Nixie tubes. As red display is eye-catching, the displayed values can be seen from a long distance away.
5.Strong interference immunity: Its current output adopts optoelectronic isolating technology. This meter has strong interference immunity and the capacity of long-distance transmission as well as excellent electromagnetic compatibility.
6.25C Conversion: The conductivity value measured at the current temperature is converted to that at 25C; thus, this conductivity meter always displays the conductivity value at 25C. Therefore, this meter is especially suitable for testing the various water solutions in power plants.
7.Automatic range switching: The measuring ranges can automatically switch within the measuring range of the electrode.
8.Communication interface: It can be easily connected to a computer to perform monitoring and communication.
9. With strong environmental adaptability, clear display, easy operation and excellent measuring performance
Main parameters
Standard | JB/T6855-93 “Industrial Conductivity Meter” |
Conductivity measuring range |
0.0~20µS/cm(Electrode: K=0.01),0.1~200µS/ cm (Electrode: K=0.1) 1.0~2000µS/cm(Electrode:K=1.0),10~20000µS/cm(Electrode: K=10.0) |
Accuracy | Conductivity±1.0%FS; temperature: ±0.5C |
Automatic temperature compensation error | ±0.5%FS |
Intrinsic error of the instrument | conductivity: ±1.0%F.S, temperature: ±0.5C(0~60C) |
Intrinsic error of electronic units | conductivity: ±0.5%F.S, temperature: ±0 3C(0~60C) |
Range for automatic temperature compensation | 0~80C, with 25C as the reference temperature |
Water sample tested | 0~80C, 0.6Mpa |
Repeatability error | ±0.2%FS±1 unit |
Stability | ±0.2%±l unit FS/24H |
Alarm error | ≤±3.0%FS |
Error caused by ambient temperature | ≤±0.5%FS |
Error by the supply voltage | ≤±0.3%FS |
Isolated current output | 4~20mA (load<750kΩ) |
Output current error | ≤±l.0%FS |
Alarm relay | AC220V, 3A |
Communication interface | RS485 or 232(optional) |
Power supply | AC 220V±22V, 50Hz±1Hz |
Protection | IP65 |
Overall dimension | 146 (length) x 146 (width) x 108 (depth) mm |
dimension of the hole | 138 x 138mm |
Working conditions | Ambient temperature: 0~60C; relative humidity <85% |
Connection tubes for inlet and outlet water | Φ8, Φ10 and Φl2 |
Last:CX-ICM-1101 industrial conducti.. Next:CX-ICM-1103 industrial conducti..