Type:CX-LPH--1608A laboratory pH meter

Illustrate:It can be widely used for continuous monitoring of PH values of the solutions in thermal power plants, chemical fertilizer, alloy, environmental protection, pharmaceutical, biochemical, foodstuff, running water, etc.

CX-LPH-1608A Laboratory PH Meter

Brief Introduction
1.CX-LPH-1608Ais a PH meter with the most powerful functions and the most convenient operation on the market.
2.In the aspects of the intelligence, the measuring property, the usage environment as well as the external structure, great improvement has been made, so the accuracy of the instruments is very high.
 
Main Features
1.Double-row nixie tubes display PH value/mV value and temperature respectively.
2.Computer-based: It adopts high-performance CPU chip, high-precision AD conversion technology and SMT technology to complete the multi-parameter measurement, temperature compensation and instrument self-checking, with high precision and good repeatability.
3.Reliability: Single board structure, touch button, no switch knob
4.25°C Conversion: Nernst electrode slope temperature compensation, pure water and ultra-pure water with addition of ammonia converted at 25°C.
5.Standard liquid temperature auto-conversion: It pre-stores the temperature curve of the standard liquid; in the calibration, it can convert pH value of the standard liquid automatically at the set temperature.
6.Auto-determination of error calibration: If the user wrongly uses the standard buffer solution in the calibration, the instrument will prompt automatically.
7.Network function: RS232 bi-directional communication, equipped with a printer or TLab8.0 communications and data processing software
 
Main Parameters

Display The double-row Nixie tube shows PH value/mV value and the temperature respectively.
Measuring range  0~14.00pH, -l999~ +1999mV, 0~99.9°C
Resolution  0.001 PH/0.01PH, 0.1mV, 0.1°C
Accuracy  ±0 005pH, ±0 2mV,  ±0 3°C
Temperature compensation range automatic: 0~99.9°C, manual: 0~99.9°C
Temperature compensation Nernst electrode slope temperature compensation, pure water and ultra-pure water with addition of ammonia converted at 25°C.
Input impedance > 1012Ω
Communication interface RS232 bi-directional communication
Output 0~1400mV
Power supply AC220V ± 22V, 50Hz ± 1Hz, external power supply
Working conditions ambient temperature: 0-60°C; relative humidity: ≤90
Power-down memory > 5 years
Calibration mode One-point calibration, two-point calibration
Standard configuration: One secondary instrument; one power supply; one 2-in-1 electrode, one temperature electrode; a set of electrode support, a set of standard buffer solution

Last:CX-LPH-1602 lab ph meter Next:CX-LPH-1608 laboratory pH meter

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
18女下面流水不遮图免费观看,99久久精品免费看国产一区二区三区,无限资源好看片高清在线,婷婷射精AV这里只有精品,国产精品天天影视久久综合网